Worcester Bosch boilers

Worcester Bosch Boiler Repair in Birmingham

Worcester Bosch Greenstar boilers show a two-character display code with a three-digit cause code, such as EA 227. Most faults homeowners see are ignition lockouts, overheat lockouts and low pressure. Check the gas, the condensate pipe and the pressure gauge, reset once, and send an enquiry if the code returns.

Last updated:

Get a quote

All gas work is carried out by Gas Safe registered engineers.

Get a quote for your Worcester Bosch boiler

Sending an enquiry is free and there is no obligation. Tell us the fault and your postcode, and we will be in touch.

Please enter your name.

Please enter a valid email address.

Please enter a Birmingham-area postcode, for example B13 9AA.

That number does not look right. Leave it blank if you prefer email.

Please tell us briefly what is wrong (a sentence is enough).

Which faults are most common on Worcester Bosch boilers?

Worcester Bosch is one of the most common boiler makes in UK homes, and its Greenstar combis and system boilers are fitted widely across Birmingham. Most of the faults owners report fall into a few groups.

Ignition lockouts (EA). The boiler tries to light, cannot detect a flame, and locks out. Worcester’s manual lists gas pressure, the flue, the ignition parts and blocked condensate pipes among the checks. In a cold snap, a frozen condensate pipe is one of the most frequent causes, and you can often clear it yourself with warm water. See our frozen condensate pipe guide.

Overheat lockouts (E9). When water is not moving through the boiler properly, it gets too hot and a safety thermostat shuts it down. Low pressure, air, sludge and pump faults are the usual culprits. Our E9 guide explains the checks.

Pressure loss. A sealed system that keeps dropping below 1 bar points to a leak or a tired expansion vessel. See boiler losing pressure.

Diverter valve faults on combis. Heating but no hot water, or the reverse, often comes down to the diverter valve on older Greenstar combis.

Servicing a Worcester Bosch boiler

An annual service checks combustion, the flue, the seals, the electrodes and the condensate trap, which covers several of the causes of an EA lockout before they strike. Keep the service record with the boiler’s paperwork, as Worcester guarantees usually depend on it. See boiler servicing for what a service includes.

Under guarantee, or out of guarantee?

If your Worcester boiler might still be within its guarantee, contact Worcester Bosch first. Repairs by someone else can affect a manufacturer guarantee, and many faults will be put right at no charge. Once the guarantee has ended, send us an enquiry and we arrange a local Gas Safe registered engineer who will diagnose the fault and give you a price before any work starts.

When should you get an engineer?

Reset a Worcester boiler once, after checking the gas, the condensate pipe and the pressure. If the code returns, the cause is inside the boiler: an electrode, a fan, a sensor, a pump or the gas valve. Those are jobs for a Gas Safe registered engineer. Fan codes such as C6 are never a homeowner fix. When you send an enquiry, include the model name from the front of the boiler and both parts of the code.

What do Worcester Bosch fault codes mean?

These meanings come from the manufacturer documents listed under the sources below. Codes vary between models and generations, so check the manual for your boiler too.

CodeManufacturer's meaningWhat to do
EA 227 / EA 229EA 227: no ionisation detected after ignition (the boiler sparked but could not prove a flame). EA 229: loss of ionisation signal during operation (the flame went out while running).Check the gas supply and the condensate pipe, then reset once. Full guide
E9 224Flue or high limit thermostat activated (safety circuit).Check the pressure gauge and that radiator valves are open, then reset once. Full guide
A1 281Pump stuck or running dry.Check the pressure gauge and top up if it is low. If it returns, get an engineer.
D4 341Primary flow temperatures rising too fast.Check the pressure and that radiators are not all turned off. If it returns, get an engineer.
C6 215 / C6 216Fan speed too high / fan speed too low.Not a homeowner fix. Send an enquiry with the full code.

Worcester Bosch boilers: common questions

Why does my Worcester boiler show two codes?

Greenstar boilers show a display code, such as EA, and a cause code, such as 227. The display code gives the type of fault and the cause code narrows it down. Note both before you reset, as an engineer will ask for them.

Is my Worcester Bosch still under guarantee?

Many Worcester boilers carry guarantees of several years, usually conditional on the boiler being registered and serviced every year. Check your paperwork or contact Worcester Bosch first if it may still be covered, as they may need to arrange the repair.

My newer Worcester shows a different style of code. Does this table apply?

Not always. The codes above come from the Greenstar i manual. Newer Worcester ranges, such as the Greenstar 4000 and 8000 series, display faults differently. Check the manual for your model, or send the code and model in your enquiry.

How often should a Worcester Bosch be serviced?

Once a year, by a Gas Safe registered engineer. Worcester, like most manufacturers, makes annual servicing a condition of its guarantees, and a service is the best way to catch worn electrodes and condensate blockages before winter.

Other makes: Vaillant , Baxi , Ideal , Glow-worm , Viessmann , Potterton , Ariston . For any other make, see the boiler repair page.

Sources: Worcester Bosch Greenstar i ErP installation, commissioning and servicing instructions (6 720 806 944), fault finding table . Boiler Repairs Birmingham is independent and is not affiliated with Worcester Bosch.