Vaillant boilers

Vaillant Boiler Repair in Birmingham

Vaillant ecoTEC boilers show faults as F followed by a number, such as F.22 for low water pressure or F.28 for a failed ignition. Many Vaillant faults trace back to water pressure and circulation. Check the pressure gauge, the gas supply and the condensate pipe, reset once, and send an enquiry if the code returns.

Last updated:

Get a quote

All gas work is carried out by Gas Safe registered engineers.

Get a quote for your Vaillant boiler

Sending an enquiry is free and there is no obligation. Tell us the fault and your postcode, and we will be in touch.

Please enter your name.

Please enter a valid email address.

Please enter a Birmingham-area postcode, for example B13 9AA.

That number does not look right. Leave it blank if you prefer email.

Please tell us briefly what is wrong (a sentence is enough).

Which faults are common on Vaillant boilers?

Vaillant’s ecoTEC range is one of the most widely fitted families of boilers in the UK, as combis, system boilers and heat-only boilers. Its fault codes are precise, which helps, and a large share of them point at the same thing: the water in the system.

Low pressure (F.22). A sealed heating system needs to hold pressure. When it drops too far the boiler shuts down for safety. Topping up through the filling loop usually gets it running, but a system that keeps losing pressure has a leak somewhere, perhaps at a radiator valve, the pressure relief valve or the expansion vessel. Our F22 guide explains how to top up safely.

Circulation faults (F.75 and F.83). The boiler checks that water is moving and warming as expected. Air in the system, a weak pump, a faulty pressure sensor or simply too little water will trigger these. Bleeding radiators and topping up the pressure solves some; the rest need an engineer. See F75.

Ignition faults (F.28 and F.29). F.28 means the boiler could not light at start-up; F.29 means it lost its flame and could not relight while running. Gas supply, a blocked condensate route and the flue all appear in Vaillant’s list of causes, alongside ignition parts. See F28.

Cold radiators. Sludge in older systems reduces circulation and can lead to the faults above. See cold radiators.

Servicing a Vaillant boiler

An annual service lets the engineer check the expansion vessel charge, the condensate trap, the electrodes and the combustion, which together cover many of the causes of the codes above. Vaillant guarantees generally depend on annual servicing, so keep the record. See boiler servicing.

When should you get an engineer?

If the pressure keeps falling, if an ignition code comes back after one reset, or if you see water inside the casing, the cause needs a Gas Safe registered engineer. The same applies to any code relating to the gas valve, the fan or the electronics. When you send an enquiry, include the full code shown on the display, the model name and how often you have needed to top up the pressure. The engineer will diagnose the fault and give a price before any work starts.

What do Vaillant fault codes mean?

These meanings come from the manufacturer documents listed under the sources below. Codes vary between models and generations, so check the manual for your boiler too.

CodeManufacturer's meaningWhat to do
F.22Safety switch-off: low water pressure. No or insufficient water in the product.Top up the pressure as shown in your user manual. If it keeps dropping, there is a leak. Full guide
F.28Failure during start-up: ignition unsuccessful.Check the gas supply and the condensate pipe, then reset once. Full guide
F.29Failure during operation: re-ignition unsuccessful. Causes listed include the gas supply stopping temporarily, flue gas recirculation and a blocked condensate duct.Check the gas supply and the condensate pipe, then reset once.
F.75No pressure change detected when the pump starts.Check the pressure, bleed radiators if there is air, then reset once. Full guide
F.83No or too little temperature change at the flow or return sensor when the burner starts. Insufficient water in the product is a listed cause.Check the pressure gauge and top up if low. If it returns, get an engineer.

Vaillant boilers: common questions

Why do so many Vaillant codes relate to water pressure?

Vaillant boilers monitor the water in the system closely. F.22 is a direct low-pressure shutdown, and Vaillant lists insufficient water among the causes of F.75 and F.83 too. So the pressure gauge is always the first thing to check on a Vaillant.

How do I reset a Vaillant boiler?

Press the reset or fault clearance button as described in your user manual. Vaillant's ecoTEC plus operating instructions advise consulting a competent person if an ignition fault cannot be cleared after three attempts. We suggest stopping after one reset if the same code returns.

Is a Vaillant the same as a Glow-worm?

Both brands belong to the Vaillant Group, and some current Glow-worm models use similar F codes, such as F22 and F28. The boilers and parts are not identical, though, so always use the manual for your own model.

Should I contact Vaillant or an independent engineer?

If the boiler is still within Vaillant's guarantee, contact Vaillant first, as an outside repair may affect it. Out of guarantee, send us an enquiry and a local Gas Safe registered engineer will diagnose the fault and price it.

Other makes: Worcester Bosch , Baxi , Ideal , Glow-worm , Viessmann , Potterton , Ariston . For any other make, see the boiler repair page.

Sources: Vaillant ecoTEC plus installation and maintenance instructions, document 0020209591 (copy of the Vaillant manual), fault code table ; Vaillant ecoTEC plus operating instructions (0020200872), troubleshooting . Boiler Repairs Birmingham is independent and is not affiliated with Vaillant.