Boiler Leaking Water: What Should You Do?

If your boiler is leaking, turn it off at the controls, isolate the electrical supply at its fused spur if you can do so safely and dry-handed, catch the water and keep it away from electrics. Leaks usually come from the pressure relief valve, pump seals, a joint under the boiler or, on older boilers, a corroded heat exchanger.

Last updated:

Get a quote

All gas work is carried out by Gas Safe registered engineers.

Get a quote for your boiler

Sending an enquiry is free and there is no obligation. Tell us the fault and your postcode, and we will be in touch.

Please enter your name.

Please enter a valid email address.

Please enter a Birmingham-area postcode, for example B13 9AA.

That number does not look right. Leave it blank if you prefer email.

Please tell us briefly what is wrong (a sentence is enough).

What should you do first?

  1. Turn the boiler off at its controls.
  2. Isolate the power at the boiler’s fused spur switch, but only if it is dry and you can reach it safely.
  3. Catch the water with a bowl or towels and move anything valuable away.
  4. Note where it is coming from: under the boiler, from a pipe, from the outside wall or from inside the case.
  5. Check the pressure gauge and note the reading.

If the leak is heavy and coming from the pipework rather than the boiler, closing the isolating valves under the boiler can slow it, if you know which they are. If not, leave them.

Where do boiler leaks usually come from?

  • Pressure relief valve. This valve opens to release water if the system pressure gets too high. Water may appear on the copper discharge pipe outside, or the valve itself may drip once it has opened a few times. The cause is often an expansion vessel that has lost its charge, letting pressure spike when the heating warms up.
  • Pump seals. The circulating pump inside many boilers has seals that wear over time and weep.
  • Joints and valves under the boiler. Compression fittings can loosen with years of heating and cooling, and isolating valves can seep around the spindle.
  • Heat exchanger. Corrosion can eventually pierce the heat exchanger, mostly on older boilers. This is usually the most expensive cause and can tip the decision towards replacement.
  • Condensate pipe and trap. A blocked or frozen condensate pipe can back water up and spill it from the trap. In winter, see frozen condensate pipe.

Is it the boiler or the heating system?

Leaks from radiators, radiator valves and pipe joints around the house also drain the boiler’s pressure, and they are often easier to fix. If the boiler itself is dry but the gauge keeps dropping, see boiler losing pressure.

What will the engineer do?

The engineer will find the source, check the pressure relief valve and expansion vessel, and test the pump and internal joints. Many leaks are a single part such as a relief valve, a seal or a fitting. You will be told the cause and the price before any work, and if the heat exchanger has failed on an older boiler you will get honest advice about whether repair is worth it.

What will the repair cost?

It depends on the part. Most boiler repairs cost £100 to £500 at typical UK market prices. The boiler repair cost guide breaks it down by fault, and the engineer gives you a price before any work starts. Send an enquiry to get one.

Boiler leaking water: common questions

Is a leaking boiler dangerous?

It can be. Water and electricity are the main risk, and a leak can damage ceilings and floors quickly. A leak on its own does not mean gas is escaping, but if you also smell gas, leave the property and call 0800 111 999.

Why is my boiler leaking from underneath?

Common causes are the pressure relief valve discharging, a loose or corroded joint on the pipes under the boiler, or a failing pump seal. A drip from the white plastic condensate pipe is a different thing and may be normal condensate flow.

Can I still use my boiler if it is leaking?

It is best not to. The boiler will lose pressure and may lock out anyway, and running it with an internal leak can damage electrical parts. Turn it off and send an enquiry.