Boiler Repairs BirminghamGet a quote

Baxi boilers

Baxi Boiler Repair in Birmingham

Baxi uses two styles of error code. Older and many current models show codes such as E133 or E118; the newer Baxi 200 to 800 Combi 2 range shows longer codes such as H.02.07. Either way, the commonest faults are low pressure and ignition. Check the pressure, gas and condensate pipe, reset once, then send an enquiry.

Last updated:

Get a quote

All gas work is carried out by Gas Safe registered engineers.

Get a quote for your Baxi boiler

Sending an enquiry is free and there is no obligation. Tell us the fault and your postcode, and we will be in touch.

Please enter your name.

Please enter a valid email address.

Please enter a Birmingham-area postcode, for example B13 9AA.

That number does not look right. Leave it blank if you prefer email.

Please tell us briefly what is wrong (a sentence is enough).

Which faults are common on Baxi boilers?

Baxi is a long-established British boiler brand, and its combis and system boilers are found in homes of every age across Birmingham, from back-boiler-era terraces to new estates. The faults owners see most often fall into a handful of groups.

Low pressure. A sealed system that drops below its minimum pressure stops the boiler. On Duo-tec, EcoBlue, Platinum and Assure models that shows as E118; on the newer Combi 2 range it shows as H.02.07. Topping up through the filling loop usually restarts it. If you are topping up every week or two, look for a leak. See boiler losing pressure.

Ignition and flame faults. E133 is the code Baxi owners search for most. Baxi’s own table calls it a gas supply fault, and the checks start with the gas supply itself, the power and the electrodes. A prepayment meter out of credit and a frozen condensate pipe are both common causes. Our E133 guide covers each step.

Circulation and overheat faults. E110 and E125 both relate to water not moving properly through the boiler. Air, sludge, a stuck pump or closed valves are the usual causes. Bleeding radiators and checking the pressure is a sensible first step.

Fan faults. E160 points at the fan, which must be checked and replaced by an engineer.

Servicing a Baxi boiler

A yearly service by a Gas Safe registered engineer checks combustion, the flue, the condensate trap and the electrodes. It is usually a condition of Baxi’s guarantee, so keep the record safe. See boiler servicing.

Under guarantee?

If your Baxi is still within its manufacturer guarantee, contact Baxi before booking a repair, as an outside repair may affect it. Out of guarantee, send us an enquiry and we arrange a local engineer who will diagnose the fault and give a price before any work starts.

When should you get an engineer?

After one reset, if the same code returns. Also straight away if water is leaking from inside the casing, the boiler is making loud bangs, or you smell gas. When you send an enquiry, include the full code exactly as it appears, the model name and whether it is a combi or system boiler.

What do Baxi fault codes mean?

These meanings come from the manufacturer documents listed under the sources below. Codes vary between models and generations, so check the manual for your boiler too.

CodeManufacturer's meaningWhat to do
E118Water pressure low (below 0.5 bar). Shown on models such as the Duo-tec, EcoBlue, Platinum and Assure.Top up the pressure as shown in your user manual. If it keeps dropping, there is a leak. Full guide
E133Gas supply fault. Baxi points engineers to the power supply, sensing electrode, spark electrode and cable.Check the gas supply and prepayment credit, and the condensate pipe in frost. Reset once. Full guide
E110Boiler maximum temperature exceeded (probable pump jammed or air in the circuit), or safety thermostat tripped.Check the pressure and bleed radiators if there is air. If it returns, get an engineer.
E125Water circulation fault.Check the pressure and that radiator valves are open. If it returns, get an engineer.
E160Fan fault.Not a homeowner fix. Send an enquiry with the code.
H.02.07Low pressure in heating circuit (permanently). Baxi 200 to 800 Combi 2 and System 2 range.Top up the pressure as shown in your user manual.
E.04.10Burner failed to ignite after 4 attempts. Baxi 200 to 800 Combi 2 and System 2 range.Check the gas supply and the condensate pipe, then reset once.

Baxi boilers: common questions

Why does my Baxi show E133 every winter?

E133 means the boiler could not establish a flame. In freezing weather, a frozen condensate pipe is a common cause, because the boiler cannot drain and locks out. Thaw the outside pipe with warm, never boiling, water and reset once.

My Baxi shows a code with letters and dots, such as H.02.07. What is it?

That style belongs to the newer Baxi 200, 400, 600 and 800 Combi 2 and System 2 range. H.02.07 means low pressure; top up as your manual shows.

Is E119 a Baxi low pressure code?

E119 is widely quoted as low pressure online, but it does not appear in Baxi's published error code table. Baxi lists E118 as low water pressure. If your boiler shows E119, check the pressure gauge and the manual for your model.

Are Baxi and Potterton the same?

Both brands belong to BDR Thermea, and Baxi's published error table also covers the Potterton Assure range, so some codes are shared. Other Potterton models differ, so check your own manual.

Other makes: Worcester Bosch , Vaillant , Ideal , Glow-worm , Viessmann , Potterton , Ariston . For any other make, see the boiler repair page.

Sources: Baxi technical support, boiler error codes . Boiler Repairs Birmingham is independent and is not affiliated with Baxi.