Ariston boilers

Ariston Boiler Repair in Birmingham

Ariston boilers, such as the Clas range, show three-digit error codes where the first digit tells you which part of the boiler is affected: 1 for the heating circuit, 3 for the electronics, 5 for ignition. 108 means the system needs filling and 501 means no flame was detected. Check the pressure and gas, then reset once.

Last updated:

Get a quote

All gas work is carried out by Gas Safe registered engineers.

Get a quote for your Ariston boiler

Sending an enquiry is free and there is no obligation. Tell us the fault and your postcode, and we will be in touch.

Please enter your name.

Please enter a valid email address.

Please enter a Birmingham-area postcode, for example B13 9AA.

That number does not look right. Leave it blank if you prefer email.

Please tell us briefly what is wrong (a sentence is enough).

Which faults are common on Ariston boilers?

Ariston is an Italian manufacturer whose Clas combis and system boilers are fitted in many UK homes. Its error codes follow a logical pattern: three digits, with the first telling you where the problem is. That makes Ariston codes easier to read than most once you know the system.

Water and pressure (1xx codes). 108 means there is not enough water in the system and it needs filling. Top up through the filling loop as your manual shows. If it comes back within days, there is a leak. 109 is the opposite, pressure above 3 bar, which can happen if a filling loop is left open. 101 is an overheat, and 103 to 107 mean water is not circulating well enough, usually because of air, sludge, closed valves or a pump problem. See boiler losing pressure and cold radiators.

Ignition and flame (5xx codes). 501 means no flame was detected. Check the gas supply first, including prepayment credit, and the condensate pipe in freezing weather. A 5 P1 or 5 P2 warning means a first or second ignition attempt failed; if the boiler then lights, it has recovered by itself. Our guide to a boiler that won’t fire up goes through the checks, and the frozen condensate pipe guide covers thawing.

Electronics (3xx codes). Most 3xx codes point to the control board. 304 is the one owners trigger themselves, by pressing reset more than five times in 15 minutes.

Why you should not keep pressing reset

Ariston builds a hard limit into its boilers: five resets in 15 minutes. After that the boiler shuts down and only runs again once the power has been disconnected. The limit exists because a fault that keeps returning has a real cause, and relighting a boiler again and again does not remove it. Reset once after the basic checks; if the code returns, stop.

Servicing an Ariston boiler

A yearly service by a Gas Safe registered engineer checks combustion, the flue, the electrodes and the condensate trap, and it usually keeps the manufacturer’s guarantee valid. See boiler servicing.

When should you get an engineer?

If a code returns after one reset, if you see 304, or if the boiler is losing pressure often, send an enquiry with the model name and the exact code. A local Gas Safe registered engineer will diagnose the fault and give a price before any work starts. If your Ariston is still under guarantee, contact Ariston first.

What do Ariston fault codes mean?

These meanings come from the manufacturer documents listed under the sources below. Codes vary between models and generations, so check the manual for your boiler too.

CodeManufacturer's meaningWhat to do
108Insufficient water (request filling).Top up the pressure as shown in your user manual. If it keeps dropping, there is a leak. Full guide
109System pressure above 3 bar.Check the filling loop is fully closed. If the gauge stays high, get an engineer.
101Overheat.Check the pressure and that radiator valves are open. If it returns, get an engineer. Full guide
103 to 107Insufficient circulation.Check the pressure and bleed radiators. If it returns, get an engineer. Full guide
501No flame detected.Check the gas supply and prepayment credit, and the condensate pipe in frost. Reset once. Full guide
5 P1 / 5 P2Warning: first or second ignition attempt failed.If the boiler then lights, no action is needed. If it keeps happening, mention it in your enquiry.
304Too many (more than 5) resets in 15 minutes.Stop resetting. Send an enquiry.

Ariston boilers: common questions

What does the first digit of an Ariston code mean?

Ariston's manual groups codes by the part of the boiler involved: 1 for the primary (heating) circuit, 3 for the internal electronics, 5 for ignition and flame detection and 6 for the air inlet and flue gas outlet. So a 5xx code is always an ignition or flame issue.

Why will my Ariston not reset any more?

For safety, Ariston boilers allow a maximum of five resets in 15 minutes. On the sixth attempt the boiler shuts down and code 304 appears, and it can only run again after the electricity supply has been disconnected. Repeated resets will not fix the cause, so send an enquiry instead.

Does an Ariston restart on its own after some faults?

Yes. Ariston describes some faults as volatile safety shut-offs, which clear by themselves once the cause goes away, and others as non-volatile shutdowns, which need the reset button. If a shutdown happens often, Ariston advises getting it checked.

Do these codes apply to every Ariston boiler?

The meanings above come from Ariston's Clas ONE R installation manual. Other Ariston ranges use a similar numbering scheme, but individual codes can differ, so check the manual for your model.

Other makes: Worcester Bosch , Vaillant , Baxi , Ideal , Glow-worm , Viessmann , Potterton . For any other make, see the boiler repair page.

Sources: Ariston Clas ONE R installation manual, table summarising error codes (library.ariston.co.uk) . Boiler Repairs Birmingham is independent and is not affiliated with Ariston.