Vaillant F75 Fault Code: What It Means and What to Do

Vaillant F75 (F.75) means the boiler detected no pressure change when the pump started, so it cannot confirm water is circulating. Vaillant lists a faulty water pressure sensor or pump, air in the heating system, or not enough water in the boiler as causes. Check the pressure, bleed the radiators, reset once, and call an engineer if F75 returns.

Last updated:

Get a quote

All gas work is carried out by Gas Safe registered engineers.

Get a quote for your boiler

Sending an enquiry is free and there is no obligation. Tell us the fault and your postcode, and we will be in touch.

Please enter your name.

Please enter a valid email address.

Please enter a Birmingham-area postcode, for example B13 9AA.

That number does not look right. Leave it blank if you prefer email.

Please tell us briefly what is wrong (a sentence is enough).

What does F75 mean on a Vaillant boiler?

When a Vaillant boiler starts its pump, it expects the water pressure sensor to register a small rise in pressure. That is how it confirms water is actually moving round the system before it lights the burner. Vaillant’s ecoTEC plus fault table describes F.75 as “No pressure change detection when starting pump”.

It is a safety lockout. A boiler that fires without proper circulation can overheat quickly, so the boiler refuses to run until the cause is fixed.

What causes F75?

Vaillant lists these causes:

  • Faulty water pressure sensor. The sensor may be reading wrongly or have failed altogether.
  • Faulty or seized pump. A pump that is stuck, weak or not powered will not create the pressure change.
  • Air in the heating installation. Air in the pump or pipework stops it moving water properly.
  • Not enough water in the boiler. If the system pressure is low, the pump cannot do its job.

The manual also points engineers to check the bypass and, on some systems, the position of an external expansion vessel. Sludge in older systems can make a weak pump worse.

What can you safely check yourself?

  1. Check the pressure gauge. If it is low, top up the system following your user manual. Low pressure on its own normally shows as F22, but the two can appear together.
  2. Bleed the radiators with the heating off, starting downstairs, then recheck and top up the pressure.
  3. Listen to the boiler when it starts. A hum with no sound of water moving, or a grinding noise, is worth mentioning in your enquiry.
  4. Reset once using the reset button.

If F75 appeared after work on the heating system, such as a new radiator or a drain-down, air is the most likely cause and the bleed-and-top-up steps often help.

When should you get an engineer?

If F75 returns after bleeding, topping up and one reset, the pump or pressure sensor needs testing. The engineer will check the pump is turning and powered, test the pressure sensor, look for air and sludge, and confirm the bypass is working. Pumps and pressure sensors are common replacement parts on ecoTEC boilers, and you will be given a price before any work begins. If the boiler is also noisy or radiators are cold in places, mention it: see radiators cold.

What will the repair cost?

It depends on the part. Most boiler repairs cost £100 to £500 at typical UK market prices. The boiler repair cost guide breaks it down by fault, and the engineer gives you a price before any work starts. Send an enquiry to get one.

Vaillant F75 fault code: common questions

Is Vaillant F75 a pump fault?

It can be. Vaillant's manual lists the pump and the water pressure sensor as the two components most likely to cause F75, along with air in the system and low water. An engineer can test which one it is.

Can air in the system cause F75?

Yes. Trapped air can stop the pump producing the pressure change the boiler is looking for. Bleeding the radiators and topping the pressure back up sometimes clears it, especially after work on the heating system.

Can I keep using my Vaillant with F75?

No. The boiler locks out because it cannot confirm water is circulating, and running without proper circulation risks overheating. Reset once after bleeding and topping up; if it returns, leave it off.

Source: Vaillant ecoTEC plus installation and maintenance instructions, document 0020209591 (copy of the Vaillant manual), fault code table . Fault code meanings can vary between models: check the manual for your boiler.