What does EA mean on a Worcester Bosch boiler?
EA is the display code Worcester Bosch Greenstar boilers use for an ignition or ionisation fault. A boiler proves its flame by passing a small current through it, called ionisation. If the boiler sparks and opens the gas valve but cannot detect that current, it shuts the gas off and locks out.
The EA is usually shown with a three-digit cause code that narrows it down. Worcester’s Greenstar i installation manual lists:
- EA 227: no ionisation detected after ignition.
- EA 229: loss of ionisation signal during operation.
Newer Worcester models, such as the Greenstar 4000 and 8000 series, show numeric codes on their text display rather than EA, so the exact display depends on your model.
What causes an EA fault?
For EA 227, Worcester’s manual tells engineers to check the dynamic gas pressure, the flue for restrictions, the gas-air ratio, the ignition unit and its connections, the gas valve, contamination inside the appliance, and blocked condensate pipes. In everyday terms:
- Gas supply: a prepayment meter out of credit, a closed gas valve or low gas pressure.
- Condensate: a frozen or blocked condensate pipe or trap, very common in winter.
- Ignition and flame sensing: a worn spark electrode, a dirty flame sensing electrode or a damaged lead.
- Gas valve and air supply: a faulty gas valve, a restricted flue or an incorrect gas-air ratio.
For EA 229 the manual adds the flame probe wiring and, again, blocked condensate pipes.
What can you safely check yourself?
- Check the gas. Does the hob light? Is a prepayment meter in credit?
- Check the condensate pipe where it leaves the wall. In freezing weather, thaw it with warm, never boiling, water. See frozen condensate pipe.
- Note the full code, including the cause code, such as 227 or 229.
- Reset once using the method in your user manual.
When should you get an engineer?
If EA comes back after you have checked the gas and the condensate pipe and reset once, the cause is inside the boiler. The engineer will test the gas pressure, inspect the electrodes and leads, clear the condensate trap and check the flue and combustion. Electrode replacements are common and often inexpensive. If your Worcester is also showing a temperature fault, see Worcester Bosch E9.